NS0-191 Questions And Answers

$68

Exam Name: NetApp Certified Support Engineer

Updated: 2020-10-23

Q & A: 60

Money Back Guaranteed
  Reviews
  Customers who bought this item also bought

Why Choose PassQuestion Network Appliance NS0-191 Exam Questions

Passquestion team uses professional knowledge and experience to provide NetApp Certified Support Engineer (NCSE) NS0-191 Questions and Answers for people ready to participate in NetApp Certified Support Engineer exam. The accuracy rate of NS0-191  exam questions provided by Passquestion are very high and they can 100% guarantee you pass the Network Appliance NS0-191  exam successfully in the first attempt. Everyone can get NS0-191  pdf with free test engine to study. PassQuestion can promise you always have the latest version for your Network Appliance NS0-191  test preparation and get your NetApp Certified Support Engineer (NCSE) certification easily.

NS0-191 Frequently Asked Questions

Q1: Can I use NS0-191 exam Q&As in my phone?
Yes, PassQuestion provides NetApp Certified Support Engineer (NCSE) NS0-191 pdf Q&As which you can download to study on your computer or mobile device, we also provide NS0-191 pdf free demo which from the full version to check its quality before purchasing.

Q2: What are the formats of your Network Appliance NS0-191 exam questions?
PassQuestion provides Network Appliance NS0-191 exam questions with pdf format and software format, pdf file will be sent in attachment and software file in a download link, you need to download the link in a week, it will be automatically invalid after a week.

Q3: How can I download my NS0-191 test questions after purchasing?
We will send NetApp Certified Support Engineer (NCSE) NS0-191 test questions to your email once we receive your order, pls make sure your email address valid or leave an alternate email.

Q4: How long can I get my NetApp Certified Support Engineer (NCSE) NS0-191 questions and answers after purchasing?
We will send NetApp Certified Support Engineer (NCSE) NS0-191 questions and answers to your email in 10 minutes in our working time and no less than 12 hours in our off time.

Working Time:
GMT+8: Monday- Saturday 8:00 AM-18:00 PM
GMT: Monday- Saturday 0:00 AM-10:00 AM

Q5: Can I pass my test with your NetApp Certified Support Engineer (NCSE) NS0-191 practice questions only?
Sure! All of PassQuestion NetApp Certified Support Engineer (NCSE) NS0-191 practice questions come from real test. If you can practice well and get a good score in our practice Q&As, we ensure you can pass your NetApp Certified Support Engineer exam easily.

Q6: How can I know my NS0-191 updated? 
You can check the number of questions, if it is changed,that means we have updated this exam ,you can contact us anytime to ask for an free update. our sales email : [email protected]

Q7: What is your refund process if I fail Network Appliance  NS0-191 test?
If you fail your NS0-191 test in 60 days by studying our study material, just scan your score report and send to us in attchment,when we check, we will give you full refund.

Q8. What other payment menthod can I use except Paypal?
If your country don't support Paypal, we offer another Payment method Western Union,it is also safe and fast. Pls contact us for the details, we will send it to your email.

Question No : 1

A customer is using DP SnapMirror replication between two clusters. The source cluster is using Clustered Data ONTAP 8.2.3
Which two versions are acceptable for the destination cluster to be operating? (Choose two.)
A. 8.1.4
B. 8.0.2
C. 8.3.1
D. 8.2.3
Answer: AD

Question No : 2

Click the Exhibit tab.







Your customer's MetroCluster controllers have generated AutoSupport notifications with a "DISK REDUNDANCY FAILED" message.
Referring to the exhibit, which component is causing the problem?
A. the SAN switch site3_3
B. the SAN switch sitel_2
C. the ATTO bridges on site3
D. the inter-switch link (ISL) between sit el and site3
Answer: D

Question No : 3

An administrator on a clustered Data ONTAP 8.3.1 system created a FlexClone of a volume containing a LUN, but the new LUN Is offline and cannot be seen by the client.
In this scenario, which two actions will solve the problem? (Choose two.)
A. The LUN must be mapped to an initiator group.
B. The new volume must be split from the parent volume before the LUN can be used.
C. The LUN must be renamed to be different from the parent LUN.
D. The LUN needs to be brought online.
Answer: AD

Question No : 4

An administrator notices that the clustered Data ONTAP 8.2.3 controllers are less responsive than normal. You use OnCommand Performance Manager but do not see obvious problems, yet, this particular issue is constant. Users are starting to complain.
Which tool would you use to collect data to help diagnose this issue?
A. Perfstat
B. Perfmon
C. AutoSupport
D. Performance Archive
Answer: B

Question No : 5

Click the Exhibit tab.







The exhibit shows an overview of a customer's network design. The customer is experiencing ping loss. As part of the troubleshooting process, you receive output by using the if grp status command from the node shell.
In this scenario, what is the customer's problem?
A. The interface group on the controller is not using the default type, causing a connection mismatch with the switch.
B. Link aggregation is not active on the switch, despite being in the design.
C. Virtual interface (VIF) is deprecated in clustered Data ONTAP because the interface group is not working as it should.
D. Virtual LANs (VLANs) are not used, which causes the interfaces to be overloaded.
Answer: C

Question No : 6

You log in to a SnapMirror destination to review the system.
Which scanner would you expect to see running?
A. active bitmap real management
B. container block reclamation
C. blocks used summary update
D. deswizzler
Answer: D

Question No : 7

You are preparing to implement a storage virtual machine (SVM) in a SAN configuration. You need to eliminate single points of failure and enable the system to survive component failures.
According to NetApp, what is the recommended minimum number of paths per LUN connecting to each node being used by an SVM in a cluster?
A. 4
B. 2
C. 1
D. 3
Answer: B

Question No : 8

Click the Exhibit tab.



The customer configured an SVM called ¡°NewSVM¡± for NFS, configured the volume, ¡°vol_nfs¡±, mounted at ¡°/vol_nfs¡±, and set up NFSv3 as shown in the exhibit. However, if they try to mount from the client with IP address 192.168.10.10, they receive a ¡°permission denied¡± error.
In this scenario, which action will solve the error condition?
A. Add a rule to the default export policy to Include the -clientmatch 192.168.10.0/24 parameter.
B. Stop and start NewSVM.
C. Associate a correct export policy to the root volume (/) of NewSVM.
D. Configure the default route for NewSVM correctly.
Answer: B

Question No : 9

Your customer has a 2-node cluster with two FAS2554 controllers running clustered Data ONTAP 8.3.
You want to upgrade non-disruptively to clustered Data ONTAP 8.3.1 using the rolling-upgrade method.
Which two operations would you perform before issuing the A storage failover takeover ¨C of node NodeA- command? (Choose two.)
A. Upgrade the service processor of all nodes.
B. Migrate all LIFs used for iSCSI and FC away from NodeA.
C. Change the default boot image to the new image.
D. Install the new software image on all nodes.
Answer: BC

Question No : 10

You receive the AutoSupport message, "CONTROLLER TAKEOVER COMPLETE PANIC" from a FAS3250 controller. You suspect a hardware issue. A core file was written to disk.
In this scenario, which two actions would you perform to obtain more information? (Choose two.)
A. You turn on "hardware debugging mode" using System Manager.
B. You collect the core file and upload it to NetApp Global Services (NGS) for analysis.
C. You boot the failed controller, carry out a giveback, and wait until the issue reoccurs.
D. You boot the failed controller to maintenance mode and execute the sldiag command.
Answer: AB

Question No : 11

You are creating a disk-partitioned root aggregate.
Which two rules are enforced automatically when accomplishing this task? (Choose two.)
A. A RAID group cannot have more than one partition from the same disk.
B. A RAID group can have more than one partition from the same disk.
C. The only supported RAID type for aggregates containing root-data partitioned disks is RAID-DP.
D. The only supported RAID type for aggregates containing root-data partitioned disks is RAID 4.
Answer: A C

Question No : 12

Microsoft SQL Server is being hosted from a Microsoft Hyper-V cluster and is mounting a LUIM from NetApp storage that contains its working databases.
In this scenario, which product would be used to ensure that consistent Snapshot copies of the database are obtained?
A. Snap Manager for MS Exchange
B. Snap Manager for Virtual Infrastructure
C. Snap Manager For SQL server
D. Snap Manager for Hyper-V
Answer: C